Question:
I restarted another server this morning and after restarting the same message appears on the other server. Now I have 2 servers with the same message:
"W1228 ROMB Batt < 24 hr"
The previous server is now showing the message:
"E1211 ROMB Batt"
this error indicates that the PERC5I RAID battery has less then 24 hours of charge left on it. This is more of a warning message. How long has the unit been online with the replacement battery?
Question:
I have not put in a replacement battery on it as yet.
What will happen if I don't replace the RAID battery on the server?
http://www.shopbattery.ca/ support center:
If running your PERC without a battery, the error would always be persistant. As far as your data, anytime there is a battery issue, the controller changes from write back to write thru mode. Controller would essentially be in a less than optimal mode without the battery as it was intended to use with the array.
You should be able to replace the ROMB battery without losing data or configuration information. When the battery drains, the PERC controller will automatically turn off the ability of the PERC RAID controller to cache updates, and it will require updates to be written to disk. This affects performance, although it may not even be noticeable by the user. When the battery has been replaced, caching should resume.
battery display :
PowerEdge R710 PowerEdge 2900 Perc 6i Perc 5i PowerEdge 1950 PowerEdge 2970 PowerEdge C2100 PowerEdge R200 PowerEdge R310 PowerEdge R410 PowerEdge R510 PowerEdge R515 PowerEdge R610 PowerEdge R710 PowerEdge R715 PowerEdge R805 PowerEdge R810 PowerEdge R815 PowerEdge R900 PowerEdge R905 PowerEdge R910 PowerEdge T105 PowerEdge T300 PowerEdge T310 PowerEdge T410 PowerEdge T605 PowerEdge T610 PowerVault NX300